A case report of blood cross-matching incompatibility caused by combining IgM and IgG antibodies against E antigen
-
Abstract: We analyzed a case of an elderly patient who presented with incompatibility reactions in multiple transfusions.Using quick centrifugation,classic anti-human globulin and polybrene method in erythrocyte spectrum,we identified that both IgM and IgG anti-E antibodies were present in the patient's serum.We selected the same ABO type,E-antigen negative red blood cell suspension for him,which showed no agglutination and hemolysis in the cross-matching tests.Our study suggested that for patients with only anti-E antibodies in the serum,same ABO type,E-antigen negative red blood cell suspension could be used for transfusion.
-
Key words:
- anti-E IgG /
- anti-E IgM /
- cross-matching
-
-
[1] 刘达庄.免疫血液学[M].上海:上海科学技术出版社, 2002:65-65.
[2] 张钦辉.临床输血学[M].上海:科学技术出版社, 2000:62-64.