补体调节缺陷对ABO血型不合输血引起溶血反应的潜在影响研究

朱青, 丁卫平, 高德兰. 补体调节缺陷对ABO血型不合输血引起溶血反应的潜在影响研究[J]. 临床血液学杂志, 2019, 32(2): 133-135. doi: 10.13201/j.issn.1004-2806-b.2019.02.015
引用本文: 朱青, 丁卫平, 高德兰. 补体调节缺陷对ABO血型不合输血引起溶血反应的潜在影响研究[J]. 临床血液学杂志, 2019, 32(2): 133-135. doi: 10.13201/j.issn.1004-2806-b.2019.02.015
ZHU Qing, DING Weiping, GAO Delan. Potential effect of complement regulation defect on hemolytic reaction induced by ABO blood type incompatibility transfusion[J]. J Clin Hematol, 2019, 32(2): 133-135. doi: 10.13201/j.issn.1004-2806-b.2019.02.015
Citation: ZHU Qing, DING Weiping, GAO Delan. Potential effect of complement regulation defect on hemolytic reaction induced by ABO blood type incompatibility transfusion[J]. J Clin Hematol, 2019, 32(2): 133-135. doi: 10.13201/j.issn.1004-2806-b.2019.02.015

补体调节缺陷对ABO血型不合输血引起溶血反应的潜在影响研究

详细信息
    通讯作者: 高德兰,E-mail:273733021@qq.com
  • 中图分类号: R457.1

Potential effect of complement regulation defect on hemolytic reaction induced by ABO blood type incompatibility transfusion

More Information
  • 目的:探讨补体调节缺陷对ABO血型不合输血引起溶血反应的潜在影响。方法:选取60例O型献血者血液标本作为研究对象,分别分离A1红细胞和抗A抗体,分析所有标本的抗A效价及补体激活情况,比较不同红细胞组补体激活和溶血情况。结果:流式细胞术检测结果显示经AET处理后的红细胞表面缺失MIRL,所有60例献血者血清IgM效价均<100,8例IgG效价<100,52例IgG效价>100,其中有20例C3b补体激活,Sperman相关性分析结果显示IgM抗A效价与补体激活显著正相关(r=0.727,P<0.01),未处理组红细胞未观察到溶血,而经AET处理组红细胞观察到溶血,20% AET处理组红细胞可见轻微溶血。结论:反应性溶血膜抑制物缺陷可能是ABO血型不合输血引起溶血反应的影响因素。
  • 加载中
  • [1]

    Lozano M,Heddle N,Williamson LM,et al.Biomedical Excellence for Safer Transfusion Collaborative.Practices associated with ABO-incompatible platelet transfusions:a BEST Collaborative international survey[J].Transfusion,2010,50:1743-1748.

    [2]

    Dunbar NM,Katus MC,Freeman CM,et al.Easier said than done:ABO compatibility and D matching in apheresis platelet transfusions[J].Transfusion,2015,55:1882-1888.

    [3]

    Karafin MS,Blagg L,Tobian AA,et al.ABO antibody titers are not predictive of hemolytic reactions due to plasma-incompatible platelet transfusions[J].Transfusion,2012,52:2087-2093.

    [4]

    Refaai MA,Fialkow LB,Heal JM,et al.An association of ABO non-identical platelet and cryoprecipitate transfusions with altered red cell transfusion needs in surgical patients[J].Vox Sang,2011,101:55-60.

    [5]

    Brodsky RA.Complement in hemolytic anemia[J].Blood,2015,126:2459-2465.

    [6]

    Frazer-Abel A,Sepiashvili L,Mbughuni MM,et al.Overview of laboratory testing and clinical presentations of complement deficiencies and dysregulation[J].Adv Clin Chem,2016,77:1-75

    [7]

    Quillen K,Sheldon SL,Daniel-Johnson JA,et al.A practical strategy to reduce the risk of passive hemolysis by screening plateletpheresis donors for high-titer ABO antibodies[J].Transfusion,2011,51:92-96.

    [8]

    Flegel WA.Pathogenesis and mechanisms of antibody-mediated hemolysis[J].Transfusion,2015,55:S47-S58.

    [9]

    Pai M,Cook R,Barty R,et al Exposure to ABO-nonidentical blood associated with increased in-hospital mortality in patients with group A blood[J].Transfusion,2016,56:550-557.

    [10]

    Zaffuto BJ,Conley GW,Connolly GC,et al.ABO-immune complex formation and impact on platelet function,red cell structural integrity and haemostasis:an in vitro model of ABO non-identical transfusion[J].Vox Sang,2016,110:219-226.

    [11]

    Zeller MP,Barty R,Aandahl A,et al.Biomedical Excellence for Safer Transfusion(BEST)Collaborative.An international investigation into O red blood cell unit administration in hospitals:the GRoup O Utilization Patterns(GROUP)study[J].Transfusion,2017,57:2329-2337.

    [12]

    Veeraputhiran M,Ware J,Dent J,et al.A comparison of washed and volume-reduced platelets with respect to platelet activation,aggregation,and plasma protein removal[J].Transfusion,2011,51:1030-1036.

    [13]

    Cooling LL,Downs TA,Butch SH,et al Anti-A and anti-B titers in pooled group O platelets are comparable to apheresis platelets[J].Transfusion,2008,48:2106-2113.

    [14]

    Fung MK,Downes KA,Shulman IA.Transfusion of platelets containing ABO-incompatible plasma:a survey of 3156 North American laboratories[J].Arch Pathol Lab Med,2007,131:909-916.

  • 加载中
计量
  • 文章访问数:  471
  • PDF下载数:  1206
  • 施引文献:  0
出版历程

目录