摘要: 目的:探讨伽利略全自动血型分析仪在血型鉴定中的应用。方法:采用伽利略全自动血型分析仪(仪器法)对7 266例样本进行ABO、RhD血型鉴定,同时用试管法作对照试验。结果:7 266例样本,仪器法ABO、RhD一次判读成功率分别为98.3%(7 145/7 266)、98.7%(7 172/7 266)。一次判读成功的ABO、RhD血型鉴定结果均与试管法相符,正确率100%。仪器法和试管法一次检测64个样本所需时间分别为35、55 min。结论:伽利略全自动血型分析仪鉴定ABO、RhD血型具有自动,快速,结果可靠,原始数据可长期保存,易于查询和举证等优点,适合大批量样本的处理。
-
关键词:
- 伽利略全自动血型分析仪 /
- ABO血型 /
- RhD血型
Abstract: Objective: To research the application of Galileo automated instrumentation systems for blood group testing.Method: Seventy-two thousand and sixty-six cases were collected.ABO and RhD blood group were tested by Galileo automated instrumentation systems (instrument method) and tube method.Result: First successful interpretation of ABO and RhD blood group testing by instrument method were 98.3% (7 145/7 266) and 98.7%(7 172/7 266) respecetively.The results were consistent with the tube method,and the accuracy rates were 100%.Time of testing 64 samples by instrument method and tube method was 35 and 55 minutes,respectively.Conclusion: Galileo automated instrumentation systems could perform in blood group testing automatically,rapidly,accurately and easily to store and quote the data,which would be suited for batch testing. -
-
[1] 周筱嫣,向东,徐忠,等.ABO血型自动化检测[J].中国输血杂志,2010,23(3):205-206.
[2] 孙秀艳,李小飞,韩雪莹.Xantus全自动血型分析仪在血型筛查工作中的应用[J].临床血液学杂志,2011,24(12):733-734.
[3] 崔娟红,赵怡雯,丁琪,等.ORTHO AutoVue Innova全自动血型分析系统在血型检测中的应用[J].中国卫生检验杂志,2010,20(8):2087-2090.
-
计量
- 文章访问数: 114
- PDF下载数: 139
- 施引文献: 0