摘要: 目的:确认血液病毒核酸检测(NAT)仪器在使用前,其性能可以满足实际检测工作要求。方法:为确认设备的检测灵敏度、特异性、重复性、可靠性和防止污染等性能,设计4个试验组:联检试验组和鉴别试验组,将生理盐水标本和NAT质控品(HBV DNA、HIV-1 RNA、HCV RNA)交叉放置于标本架上,进行NAT联检和鉴别检测;仪器比对组用同一批献血者标本在同类型的2台仪器上进行检测;污染评估试验组用生理盐水作为阴性标本进行NAT联检。结果:所有NAT检测结果均与预期一致。结论:血液病毒核酸检测设的各项性能满足实际检测工作要求。Abstract: Objective:To confirm whether the performance of blood virus nucleic acid testing (NAT) instrument before use can satisfy the test requirement. Method:For verify the detection sensitivity, specificity, repeatability, reliability, and prevent pollution of blood virus nucleic acid testing instrument,four experimental groups was designed. Multiplex and discriminatory assays groups:specimens of physiological saline and NAT quality control material (HBV DNA, HIV-1 RNA, HCV RNA) cross placed on shelves, perform multiplex and discriminatory assays. Instrument contrast group using the same specimens on the same type instrument for testing, and prevent pollution group:physiological saline as negative samples for multiplex assays testing. Result:All NAT test results were in line with expectations. Conclusion:Various performance of blood virus nucleic acid testing instrument could satisfy the requirement of actual test work.
-
Key words:
- nucleic acid testing /
- instrument /
- performance qualification
-
-
[1] Shimian Zou, Kerri A. Dorsey, Edward P. Notari, et al. Prevalence, incidence, and residual risk of human immunodeficiency virus and hepatitis C virus infections among United States blood donors since the introduction of nucleic acid testing[J]. Transfusion, 2010,50:1495-1504.
[2] Roth W K,Busch M P,Schuller A,et al. International survey on NAT testing of blood donations:expanding implementation and yield from 1999 to 2009[J]. Vox Sang,2012,102:82-90.
[3] B cker W,Clark M,Desaint C,et al. ISBT-Guidelines for validation and maintaining the validation state of automated systems in blood banking[J].Vox Sanguinis,2003,85:1-14.
[4] 罗海玲,田兆嵩,梁佩贤.确认控制[M]//余晋林,朱业华,田兆嵩.血站质量管理培训教程.北京:科学出版社,2009:367-68.
[5] ISBT. Guidelines for Validation of Automated Systems in Blood Establishments[J].2nd ed Vox Sanguinis,2010,98:1-19.
[6] 吴亚玲,祝宏,董杰.血液核酸筛查室内质控品浓度选择的探讨[J].中国输血杂志,2013,26(2):170-171.
[7] Hollinger FB, Sood G. Review Occult hepatitis B virus infection:a covert operation[J]. J Viral Hepat,2010,17:1-15.
[8] 颜秀娟,邱昌文,石庆秋,等.核酸血液筛查污染控制措施[J].中国输血杂志,2012,25(8):807-808.
[9] 冷婵,王中梅,于磊,等.血站核酸检测实验室风险识别、评估及控制方法探讨[J].中国输血杂志,2011,24(7):547-550.
[10] 邹荣良.基质效应在临床化学检测中的影响研究[J].中国误诊学杂志,2009,34(9):8391-8392.
[11] 黄宏耀,王长翠,李玲,等.建立新鲜健康抗凝血多仪器比对室内质量控制措施的探讨[J].国际检验医学杂志,2008,29(11):1033-1034.
[12] 张瑶婵,张泳,郭康社.设备确认存在的问题及分析[J].中国输血杂志,2010,23(11):909-910.
-